If you are experiencing a problem with the temperature or compression within your Refrigeration, you may need to replace a broken Freezer Compressor. The gas compressor in your Refrigeration helps increase the pressure of gas in the unit, and it appears as a large, round steel shell within the lower area of the Refrigeration. You can manually replace the compressor by disconnecting the compressor from its wire connections.
1 Remove the refrigerant from the freezer unit. Connect the gauges to the freezer and the recovery machine using the piercing valve.
2 Unplug the freezer and plug in the recovery unit. Turn on the recovery machine and allow it to run until the compound gauge reads "0" psig.
3 Close the gauge valves and close the refrigerant tank valve. Remove the gauge hose and piercing valve from the compressor tube.
4 Light the acetylene torch and unsolder the two lines attached to the compressor. Use the locking pliers to pull each line from its soldered joint while heating it with the acetylene torch.
5 Secure mounting bolts and tighten securely. Insert the suction and discharge lines into the fittings on the compressor. Put some flux on the joints and solder the joints using the propane torch and silver solder. Attach the piercing valve to the third tube protruding from the compressor. Solder the end shut.
6 Use the adjustable wrench to remove the four mounting bolts that hold the compressor in place. Hold the compressor firmly and lift it off its base. The new compressor should be an exact replacement and should fit on the same mounts. Prepare the new AC Refrigeration Compressor by removing all rubber seals from protruding pipes. Attach rubber mounts to the four mounting points.
7 Replace the dryer whenever the system is opened to the atmosphere. The dryer is located at the outlet of the condenser. It is a small cylindrical unit. Unsolder it with the acetylene torch and solder the new dryer to the condenser and the capillary line.
8 Attach the manifold gauge. Attach the vacuum pump in place of the recovery machine. Open the blue handle on the manifold gauge and start the vacuum pump. Allow the vacuum pump to run for 20 minutes to an hour. You should have a good vacuum at least 29 inches Hg vacuum. Close gauge and stop vacuum pump. The unit should hold the vacuum. This indicates that there are no leaks.
9 Pinch the process tube in front of the piercing valve with the pinching tool. Remove piercing valve and solder hole shut.
10 Attach a refrigerant drum with clean fresh refrigerant, in place of the vacuum pump. Purge air from the lines and break the vacuum. Start the compressor. Continue charging using the frost line method. That is visually inspecting the evaporator. When it is fully frosted it is fully charged. Close the gauge. Close the refrigerant drum.
If you want to know more about Compressor,please enter the following link:Piston Compressor.